{"product_id":"ieb2002barkg-2m-pur-rt","title":"IE9203 Inductive Proximity Sensor, IEB2002BARKG\/2M\/PUR RT","description":"\u003cp\u003e\u003cstrong\u003eIE9203 inductive proximity sensor\u003c\/strong\u003e. Model reference: IEB2002BARKG\/2M\/PUR RT. 2 mm sensing range, M8 threaded body and 2 m PUR cable.\u003c\/p\u003e\n\u003ch3\u003eCheck the two-wire input before ordering\u003c\/h3\u003e\u003cp\u003eThis is a two-wire, normally open DC sensor. The IE9203 datasheet specifies a 5 mA minimum load and up to 0.6 mA leakage current. Check the connected input against these requirements, the 10–55 V DC supply and the wiring diagram; matching the M8 body alone does not confirm compatibility.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/fr\/pages\/model-check?model=IE9203+%2F+IEB2002BARKG%2F2M%2FPUR+RT+%2F+SKU%3A+WCS-VHTDQUBTO8\u0026amp;search=WCS-VHTDQUBTO8\u0026amp;product_url=%2Fproducts%2Fieb2002barkg-2m-pur-rt%3Fvariant%3D50261350416632\"\u003eCheck my model and connection\u003c\/a\u003e — send the existing part label and equipment reference.\u003c\/p\u003e\n\u003ch3\u003eProduct characteristics\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical design\u003c\/th\u003e\n\u003ctd\u003ePNP\/NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput function\u003c\/th\u003e\n\u003ctd\u003enormally open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensing range [mm]\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing\u003c\/th\u003e\n\u003ctd\u003ethreaded type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions [mm]\u003c\/th\u003e\n\u003ctd\u003eM8 x 1 \/ L = 42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eElectrical data\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating voltage [V]\u003c\/th\u003e\n\u003ctd\u003e10...55 DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutputs\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical design\u003c\/th\u003e\n\u003ctd\u003ePNP\/NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput function\u003c\/th\u003e\n\u003ctd\u003enormally open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMax. voltage drop switching output DC [V]\u003c\/th\u003e\n\u003ctd\u003e4.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum load current [mA]\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMax. leakage current [mA]\u003c\/th\u003e\n\u003ctd\u003e0.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePermanent current rating of switching output DC [mA]\u003c\/th\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSwitching frequency DC [Hz]\u003c\/th\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShort-circuit protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType of short-circuit protection\u003c\/th\u003e\n\u003ctd\u003epulsed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverload protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDetection zone\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensing range [mm]\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReal sensing range Sr [mm]\u003c\/th\u003e\n\u003ctd\u003e2 ± 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating distance [mm]\u003c\/th\u003e\n\u003ctd\u003e0...1.62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccuracy \/ deviations\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCorrection factor\u003c\/th\u003e\n\u003ctd\u003esteel: 1 \/ stainless steel: 0.7 \/ brass: 0.5 \/ aluminium: 0.4 \/ copper: 0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHysteresis [% of Sr]\u003c\/th\u003e\n\u003ctd\u003e3...15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSwitch point drift [% of Sr]\u003c\/th\u003e\n\u003ctd\u003e-10...10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOperating conditions\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient temperature [°C]\u003c\/th\u003e\n\u003ctd\u003e-25...80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTests \/ approvals\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMC\u003c\/th\u003e\n\u003ctd\u003eEN 60947-5-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEN 55011\u003c\/th\u003e\n\u003ctd\u003eclass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMTTF [years]\u003c\/th\u003e\n\u003ctd\u003e2460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eMechanical data\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight [g]\u003c\/th\u003e\n\u003ctd\u003e45.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing\u003c\/th\u003e\n\u003ctd\u003ethreaded type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eflush mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions [mm]\u003c\/th\u003e\n\u003ctd\u003eM8 x 1 \/ L = 42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThread designation\u003c\/th\u003e\n\u003ctd\u003eM8 x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterials\u003c\/th\u003e\n\u003ctd\u003ebrass white bronze coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDisplays \/ operating elements\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay switching status\u003c\/th\u003e\n\u003ctd\u003e1 x LED, red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccessories (supplied)\u003c\/th\u003e\n\u003ctd\u003elock nuts: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eRemarks\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePack quantity\u003c\/th\u003e\n\u003ctd\u003e1 pcs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eElectrical connection\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003eCable: 2 m, PUR; 2 x 0.14 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eParticularly short housing\u003c\/li\u003e\n\u003cli\u003eFor use where space is restricted\u003c\/li\u003e\n\u003cli\u003eRobust metal housing for use in harsh industrial environments\u003c\/li\u003e\n\u003cli\u003eVery high switching frequency\u003c\/li\u003e\n\u003cli\u003eTwo-wire technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/media.ifm.com\/dam\/2e864391-3077-4b48-8b0f-b8b4bbae95a6\/Original\/IE9203-00_EN-GB.pdf\"\u003eManufacturer model datasheet\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/selectumllc.com\/attachments\/ifm\/IE9203-datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIE9203 manufacturer technical reference, third-party hosted (PDF)\u003c\/a\u003e. This reference does not verify the supplied item.\u003c\/p\u003e","brand":"West Control Supply","offers":[{"title":"Default Title","offer_id":50261350416632,"sku":"WCS-VHTDQUBTO8","price":240.36,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0849\/0378\/8792\/files\/61fSWvd-e8L.jpg?v=1790765277","url":"https:\/\/westcontrolsupply.com\/fr\/products\/ieb2002barkg-2m-pur-rt","provider":"West Control Supply","version":"1.0","type":"link"}